Smarter Marine Energy Management. Greater Operational Efficiency.
SmartHarmo™ brings together the energy-saving power of variable frequency drives (VFDs) and advanced harmonic mitigation. The result: more efficient vessel operations while helping protect generators, transformers and motors.
Request Technical Brief
The Challenge: Hidden Energy Losses and Harmonic Stress
Marine vessels can lose valuable energy through unoptimised engine-cooling seawater pumps, diesel generator overconsumption and mismatched engine-room motors. Traditional VFD upgrades may not deliver the fuel savings you expect, while the harmonic currents they generate stress shipboard electrical infrastructure.
On a typical container vessel, standard six-pulse VFDs produce 35–45% current distortion (THDi) at rated load, and even more at partial loads—causing IEEE 519 violations, generator derating of 15–25%, and transformer derating of 20–24%.
Motor and Generator Core Damage
Excessive harmonic currents increase eddy-current and hysteresis losses, overheating stator and rotor cores.
Interwinding Faults
Voltage distortion and high dv/dt stress accelerate insulation degradation across motor and transformer windings.
Reduced Bearing Life
High-frequency shaft currents induced by unmitigated VFDs cause premature bearing pitting and mechanical failure.
The SmartHarmo™ Solution
Combines VFD-driven efficiency with advanced harmonic mitigation in a single energy-efficiency system that intelligently controls auxiliary machinery.
Dynamic Flow Optimisation
Continuously adjusts pump speed to match real-time cooling system demand.
Temperature-Differential Mode
Modulates seawater flow precisely according to temperature differentials across cooling circuits.
Best Efficiency Point (BEP) Tracking
Keeps pump operating efficiency at its peak even under partial-load sea conditions.
Self-Adjusting Control
Automatically adapts control curves to the hydraulic characteristics of each shipboard system.
Technical Specifications
Direct performance comparison between SmartHarmo™ and a conventional six-pulse marine VFD.
| Parameter | SmartHarmo™ | Traditional VFD |
|---|---|---|
| Current distortion (THDi) | 3–8% | 35–45% |
| Displacement power factor | 0.96–0.99 | 0.75–0.85 |
| Distortion power factor | 0.85–0.92 | — |
| Generator derating | 3–8% (0% in comparison case) | 15–25% |
| Transformer derating | 5–12% | 20–24% |
| Harmonic filtering | Active and passive options | — |
| Monitoring | Real-time power quality | No real-time optimisation |
| Typical payback | 8–16 months | — |
Key Benefits for Your Vessel
Proven Energy Savings
50–58% energy savings demonstrated on engine-cooling seawater pumps.
Faster ROI
Typical capital payback achieved in 8–16 months of sea-going operation.
Lower Emissions
Significant reductions in CO2, SOx and NOx through reduced auxiliary generator load.
Recovered Capacity
Reclaims generator and transformer capacity otherwise lost to harmonic derating.
Greater Reliability
Reduces thermal and electrical stress on generators, transformers and motors.
Improved Performance
Optimised auxiliary machinery performance across varying sea-going profiles.
Future-Ready Compliance
Supports IEEE 519, marine class rules, and evolving emissions regulations.
Scalable Solution
Tailored to the specific electrical topology and load profile of your vessel.
Evaluate SmartHarmo™ for Your Vessel
Request a tailored harmonic audit and seawater pump energy-savings projection from our Singapore engineering team.