Accurate Emissions Data. Fewer Penalties. One System for Every Stack.

i-CEMS™ uses Fourier Transform Infrared (FTIR) spectroscopy to measure CO₂, CO, SO₂, SO₃, NOx, CH₄, N₂O and NH₃ from a single sample stream—automatically logging, alarming and reporting for IMO DCS, EU MRV, CII and MARPOL Annex VI.

Request i-CEMS™ Datasheet
i-CEMS Continuous Emission Monitoring System FTIR analyser unit
Accuracy
0.5 ppm
Repeatability
< 1%
Range (cm⁻¹)
900–5000

Why i-CEMS™? Built for Modern Marine Operations

Conventional single-gas sensors miss the full emission profile. FTIR spectroscopy captures 10+ gases simultaneously with minimal upkeep.

MULTI-GAS

10+ Gases at Once, Expandable

Measures CO2, CO, SO2, SO3, NOx, CH4, N2O, NH3 and more simultaneously. New gases are added via software upgrade with no hardware swap.

0.5 PPM

Trace-Level Accuracy

Resolves concentrations to within 0.5 ppm across a 900–5000 cm⁻¹ spectral range, outperforming typical electrochemical and NDIR analysers.

< 1% REPEATABILITY

Minimal Calibration & Low Upkeep

Zero/span auto-calibration against reference gas cylinders keeps readings traceable while minimising routine servicing.

4 GAS INPUTS

Multi-Stack, One Unit

A single analyser with four gas inputs handles multiple exhaust stacks without cross-contamination.

DCS / PLC

Real-Time Alarms & Integration

Threshold exceedances are flagged instantly and routed directly to the vessel DCS or management system via signal isolator and PLC/UPS cabinet.

AUDIT READY

Compliance-Ready Reporting

Spectra plots, trend graphs, heat maps and custom real-time dashboards support regulatory audits with historical data logging.

System Architecture

How It Works: Three Stages from Exhaust to Evidence

STAGE 101 / 03

Acquisition

Multi-gas sampling, gas cell loading, pressure adjustment, calibration and collection of background and sample spectra.

STAGE 202 / 03

Processing

Baseline correction and smoothing, peak identification and integration, plus an automatic quality check that repeats measurement on failure.

STAGE 303 / 03

Reporting

Near-real-time concentration calculation, database logging and automated regulatory documentation.

More Than Compliance: Protect Your Investment

Save Crew Time

Automated data collection cuts paperwork and manual emissions calculations.

Avoid Costly Non-Compliance

Accurate continuous monitoring lowers the risk of penalties and reporting errors.

Reduce Operating Costs

Fewer monitoring devices and lower maintenance reduce total lifecycle costs.

Future Ready

Software upgrades keep the system aligned with evolving regulations and CII improvement.

Long Lifecycle

Engineered to protect your vessel compliance investment for 10+ years.

Where It’s Applied

Designed for marine exhaust stacks and adaptable to industrial and research gas-analysis environments.

Vessel emissions monitoring Greenhouse gas quantification Industrial gas analysis & process control Trace gas analysis Scientific research
Supported Regulatory Frameworks
IMO DCS · EU MRV · CII · MARPOL Annex VI

Simplify Multi-Stack Emissions Compliance

Schedule an engineering review for your vessel exhaust configuration and IMO DCS / EU MRV reporting.